• Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us
  1. Tyco-Fire
  2. Products and Solutions
  3. Corrosion Solutions
  4. TAV-D Dry System Air Vent
Product Image_TAV-D_1
Product Image_TAV-D_2
Product Image_TAV-D_3
Product Image_TAV-D_4
  • Thumb Image_TAV-D_1.png
  • Thumb Image_TAV-D_2.png
  • Thumb Image_TAV-D_3.png
  • Thumb Image_TAV-D_4.png

TAV-D Dry System Air Vent

Designed for use with NG-1 Nitrogen Generators

System Type Dry, Preaction
Product Type Oxygen Removal Vent
Back to Top

TGSP Gas Sampling Port

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
    Contact Us

    Automatic Oxygen and Nitrogen Venting

    The Tyco® TAV-D Dry System Air Vent provides oxygen venting in dry pipe fire sprinkler systems. As a fire sprinkler system is filled with a continuous supply of nitrogen gas from the Tyco® Model NG-1 Nitrogen Generator, the air vent allows oxygen-rich gas to be vented from the fire sprinkler system. Over a short period of time, the TAV-D will almost completely remove oxygen from the fire sprinkler system (< 2% oxygen). The vent is also installed to provide source gas when used in conjunction with the Tyco® TSGA SMART Gas Analyzer. There are two Tyco® air vent models available — the TAV-D and also the TSV-D. Both units operate as described above, but the TSV-D model includes an electronic solenoid valve wired to a control panel that automatically closes the vent once the desired nitrogen concentration is reached.
    Automatic Oxygen and Nitrogen Venting

    Features

    • Can be installed directly on system risers
    • Nitrogen gas sampling port for use with THGA or TSGA Gas Analyzers
    • Automatic float shut-off in the event of a system trip
    • Must be manually closed after a 14-day nitrogen fill-and-purge process
    • Includes a failsafe back-pressure regulator
    • Support hanger not required

    Benefits

    Reduce Corrosion
    Reduce Corrosion

    Nitrogen replaces corrosion-causing oxygen.

    Extend Useful Life
    Extend Useful Life

    Reducing corrosion can extend the service life of a fire sprinkler system.

    Minimize Business Interruption
    Minimize Business Interruption

    System leaks due to corrosion can lead to costly downtime, and reducing corrosion helps keep systems healthy and operational.

    Related Products

    TSV-D SMART Dry System Air Vent

    TSV-D SMART Dry System Air Vent

    THGA Handheld Gas Analyzer

    THGA Handheld Gas Analyzer

    TSGA SMART Gas Analyzer

    TSGA SMART Gas Analyzer

    Technical Specification

    Dimensions 12.0 in. (W) x 4.65 in. (D) x 9.1 in. (H) (305 mm (W) x 118 mm (D) X 231 mm (H)) Sensor Type Dry, Preaction
    Service Pressure Up to 175 psig (12 bar) System Connection 1-inch NPT Male
    Temperature Range 40°F to 120°F (4.5°C to 49°C)    

    Technical Resources

    Document Name
    Description
    Language
    Resource Type

    Data Sheet

    TFP1262 Technical Data Sheet  (English)

    TAV-D Dry System Air Vent - TFP1262 (English) Air Vent, Dry

    English Data Sheet
    VIEW

    Brochure

    Corrosion-Solutions-Fire-Sprinkler-System_7-20 (English)

    Corrosion Solutions for Fire Sprinkler Systems

    English Brochure
    VIEW

    Brochure

    Tyco-Storage-Fire-Sprinkler-Applications_10-20 (English)

    Fire Sprinkler Solutions for Storage Applications

    English Brochure
    VIEW

    Video

    NG-1 Nitrogen Generator (English)

    NG-1 Nitrogen Generator Overview

    English Video
    VIEW

    Video

    Dry Pipe Nitrogen Inerting (DNPI) Process (English)

    Dry Pipe Nitrogen Inerting (DNPI) Process

    English Video
    VIEW

    Video

    Product Demo of the NG-1 Nitrogen Generator (English)

    NG-1 Nitrogen Generator Demonstration

    English Video
    VIEW

    Data Sheet

    TFP1262_ES Technical Data Sheet – Spanish Translation (Spanish)

    TAV-D Dry System Air Vent - TFP1262 (Spanish) Air Vent, Dry

    Spanish Data Sheet
    VIEW

    Data Sheet

    TFP1262_DE Technical Data Sheet – German Translation (German)

    TAV-D Dry System Air Vent - TFP1262 (German) Air Vent, Dry

    German Data Sheet
    VIEW

    Data Sheet

    TFP1262_SV Technical Data Sheet – Swedish Translation  (Swedish-Sweden)

    TAV-D Dry System Air Vent - TFP1262 (Swedish) Air Vent, Dry

    Swedish-Sweden Data Sheet
    VIEW

    Data Sheet

    TFP1262_DA Technical Data Sheet – Danish Translation 

    TAV-D Dry System Air Vent - TFP1262 (Danish) Air Vent, Dry

    Data Sheet
    VIEW

    Data Sheet

    TFP1262_FI Technical Data Sheet – Finnish Translation 

    TAV-D Dry System Air Vent - TFP1262 (Finnish) Air Vent, Dry

    Data Sheet
    VIEW

    Data Sheet

    TFP1262_IT Technical Data Sheet – Italian Translation (Italian-Italy)

    TAV-D Dry System Air Vent - TFP1262 (Italian) Air Vent, Dry

    Italian-Italy Data Sheet
    VIEW

    Revit File

    Model TAV-D Rev (English)

    TAV-D Rev-1 - TFP1262

    English Revit File
    VIEW

    Revit File

    Model TAV-D (English)

    TAV-D - TFP1262

    English Revit File
    VIEW
    No resource found for selected filter

    Back

    Next

    Looking for more Resources
    A laptop on a desk with a finger pointing at a screen

    SprinkCAD Software Suite 

    Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

    Learn about our all-in-one software package
    Contact Us
    • Antifreeze
    • Corrosion Solutions
    • CPVC
    • Fire Grooved
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Sprinklers, Nozzles and Accessories
    • Valves, Devices, and Components
    • Technical Datasheets
    • Design Files
    • Tech Data Update Summaries
    • Regional Product Catalogs
    • Americas Price Book
    • Insights
    • WARNING: Cancer & Reproductive Harm
    • Regulatory & Health Warnings
    • SVHC statement - CPVC products containing UV-238
    Tyco logo
    Connect With Us
    • LinkedIn logo
    • Twitter X logo
    • YouTube Play logo
    Johnson Controls logo
    © 2025 Johnson Controls. All Rights Reserved.
    • JohnsonControls.com
    • Privacy
    • Legal
    • Terms and Conditions