• Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us
  1. Tyco-Fire
  2. Products and Solutions
  3. Valves, Devices, and Components
  4. Accelerators
  5. Vizor Electronic Dry Pipe Accelerator
Product Image_VIZOR_1
Product Image_VIZOR_2
Product Image_VIZOR_3
Product Image_VIZOR_4
  • Thumb Image_VIZOR_1.png
  • Thumb Image_VIZOR_2.png
  • Thumb Image_VIZOR_3.png
  • Thumb Image_VIZOR_4.png

Vizor Electronic Dry Pipe Accelerator

Quick-opening accelerator

Electronics don’t have to be complex: Compared to the many complex parts of traditional mechanical accelerators, the Vizor electronic accelerator has just one moving part.

  • Provides operation of a dry pipe valve within four seconds
  • Unique air-pressure monitoring triggers upon detection of a sustained drop in air pressure
  • Available in the US and Canada
Back to Top

Vizor Electronic Dry Pipe Accelerator

  • Overview
  • Features
  • Benefits
  • Technical Resources
  • Related Products

    Helps Reduce Fluid Delivery Times

    Vizor’s quick trip time cuts fluid delivery time on an average-size system by nearly 20 seconds. The accelerator takes two pressure readings every second, which allows it to differentiate between normal system pressure loss over time and the operation of a sprinkler. This means reduced false trips and earlier response to an activated sprinkler.
    Helps Reduce Fluid Delivery Times

    Features

    • Easy button-press for test and reset function
    • Battery backup in the event of primary power failure
    • UL and C-UL Listed, FM Approved for use with Tyco® DPV-1 dry pipe valves
    • Electronically self-supervising technology, like that used in typical alarm panels for alarm and detection systems
    • Reduce valves and risers to reduce project costs – with SprinkCAD design software or Tyco® Design Services, you can optimize your installation layout
    • Available in the US and Canada

    Benefits

    Faster Trip Time
    Faster Trip Time

    Deliver water sooner with a quicker, more consistent trip time compared to a mechanical accelerator.

    Reduce False Trips
    Reduce False Trips

    Active air pressure monitoring adjusts to small and slow changes in pressure system, but trips when there is a steady pressure drop.

    Easy Resetting
    Easy Resetting

    Electronic reset eliminates the complicated breakdown, overhaul, and reassembly of a mechanical accelerator.

    Technical Resources

    Document Name
    Description
    Language
    Resource Type

    Data Sheet

    TFP1105 (English)

    Vizor Electronic Dry Pipe Accelerator - TFP1105 (English) Electronic Accelerator (Quick Opening Device) for Dry Pipe Systems

    English Data Sheet
    VIEW

    Brochure

    Tyco-Fire-Valves-System-Components (English)

    Fire Valves and System Components

    English Brochure
    VIEW

    Brochure

    FSP2018017_VIZOR Broch_Aug 2018_web (English)

    Vizor Electronic Dry Pipe Accelerator

    English Brochure
    VIEW
    No resource found for selected filter

    Back

    Next

    Looking for more Resources

    Related Products

    DPV-1 Pre-trim Dry Pipe Valve

    DPV-1 Pre-trim Dry Pipe Valve

    ACC-1 Dry Pipe Accelerator

    ACC-1 Dry Pipe Accelerator

    QRS-2 Quick Release Switch

    QRS-2 Quick Release Switch

    A laptop on a desk with a finger pointing at a screen

    SprinkCAD Software Suite 

    Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

    Learn about our all-in-one software package
    Contact Us
    • Antifreeze
    • Corrosion Solutions
    • CPVC
    • Fire Grooved
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Sprinklers, Nozzles and Accessories
    • Valves, Devices, and Components
    • Technical Datasheets
    • Design Files
    • Tech Data Update Summaries
    • Regional Product Catalogs
    • Americas Price Book
    • Insights
    • WARNING: Cancer & Reproductive Harm
    • Regulatory & Health Warnings
    • SVHC statement - CPVC products containing UV-238
    Tyco logo
    Connect With Us
    • LinkedIn logo
    • Twitter X logo
    • YouTube Play logo
    Johnson Controls logo
    © 2025 Johnson Controls. All Rights Reserved.
    • JohnsonControls.com
    • Privacy
    • Legal
    • Terms and Conditions